NAVIGATIONAL IMPLANT PLACEMENT IN THE DELAYED PROTOCOL: AN EVIDENCE-BASED REVIEW

Salimova M.A.

Tashkent State Medical University

Shukhratullaeva M.A.

Tashkent State Medical University

Keywords: guided implant surgery; dynamic navigation; delayed implant placement; late placement; accuracy; CBCT; static computer-aided implant surgery


Abstract

Guided implant surgery transfers a digital, prosthetically driven plan to the patient with a static template, a dynamic navigation system, or a robot. In healed ridges (delayed or late placement, ITI types 3–4), the anatomy is stable and soft tissue has matured, which makes the digital plan reproducible. This review summarises the classification of placement timing, the biology of the healed ridge, the accuracy of static, dynamic and robotic systems, factors that change accuracy, clinical outcomes (survival, complications, marginal bone), and practical workflow and safety rules. Pooled data show mean deviations of about 1.0–1.2 mm at the entry point, 1.2–1.4 mm at the apex and 3–3.6° in angulation, which is why a safety margin of at least 2 mm from vital structures is recommended [8,15,16]. Long-term data specific to healed ridges are limited, and several conclusions below come from mixed populations, so they should be read with that in mind..